Customization: | Available |
---|---|
After-sales Service: | Response in 12 Hours |
Warranty: | 12 Months |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description
NFPA 701 for fire-retardant fabric and film material combustion test, published by the National Fire Protection Association.The standards are widely used in the United States, for public curtains and other hanging fabrics, which not water resistant fabric.
This Flame Propagation Tester is made according to the US Fire Department NFPA 701 method.It is suitable for single or multiple layers of fabric panel for gram more heavily than 700g / m2 (21od/yd2) fabrics, and polyethylene-coated fabric etc.
Standard:
NFPA NFPA 701: 2004,2010 Edition Test Method 2
Main Features
1, Dimensions: length 500 X width 500 X height 2420mm .
2, Burner size: diameter 9.5 mm + 1.5, -0 mm, length 100 ± 10 mm.
3, Weight: 110kg.
4, Flow meter range: 0 ~ 66cc/min.
5, Stainless steel cabinet structur.
6, Stainless steel wire is supplied with Flame Propagation Tester .
7, The Flame Propagation Tester uses imported Bunsen burner conforms to ASTM D 5025 standard.
8, Theflame angle of imported Bunsen burner is 25°.
9, Automatic ignition and extinguished mode.
10, Needle valve control the flame height
11, Timer range: 0-99s±0.1 seconds
12, Operating pressure of the burner: 17.5 kPa ± 2.0 kPa
13, Operating gas flow rate: 113 L/hr ± 3 L/hr
14, Flame height: 280±12 mm.
15, Open box structure.
16, Calcium silicate board cabinet, stainless steel exterior package.
17, Merkel Burner: Burner for heat 10,500 Btu/Hour.
18, Gas release and burning time is set automatically 20 seconds.
19, Standard sample clip
20, Power: 220V, 50Hz, 110W
Test Method 1 vs Test Method 2... What's the difference?
Test Method 1 applies to materials with a density less than or equal to 700/b/m². Items that fall within this category would be draperies/curtains or other fabrics used as window treatments. They are single layer fabrics. It is usually single-layer fabrics. The exception to this is when more than one layer is fastened together by sewing or other mechanical means.
Test Method 2 applies to plastic films, vinyl-coated fabric such as blackout linings, or lined curtains that have a vinyl coating. Decorative materials other than fabrics fall within this category. fabrics with or without reinforcement or a backing that is used as decoration inside a building must also pass Test 2. This also includes permanent enclosures for building under construction. Of course awnings, plastic tarps, tents, banners or membrane structures must meet the Test 2 requirements. These items cannot be tested to Test 1, only Test 2. If you aren't sure, please contact the NFPA or visit their website. The information is quite extensive and detailed. The purpose of this article was to give the reader a look into the fire certifications that apply to fire retardant/ flame retardancy of plastic sheeting.