ASTM E662 Optical Smoke Density Test Device for Plastic and Cable

After-sales Service: Response in 12 Hours
Warranty: 12 Months
Test Standard: ISO 5659-2,Nes 711,ASTM E662,Nepa 258
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable pictures & photos
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable
US $20,000-30,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
SDB-T
Chamber Size
914mm*914mm*610mm
Power Supply
110V AC 60Hz / 230V AC 50Hz, 30A
Weight
210kg
Dimension
2150 (H) X 1650 (L)X840 (D)
Output of Furnace Heater
25 Kw/M2
Diameter of Optical Window
75mm
Output of Conical Heater
50 Kw/M2
Display
LCD
Test Object
Plastic,Cables etc
Control
Industrial Computer
Software Language
English
OEM Service
Available
Color
White and Black
Air Flow Meter Range
0 ~ 1000 Ml/Min
Transport Package
Plywood Case
Specification
Stainless steel
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
10 Sets/Month

Product Description

Introduction:

NBS Smoke Index Test Device as proved to be one of the most versatile fire testing instruments since its inception in the 1980s.

It is the most widely accepted apparatus for the measurement of smoke from burning materials and measures specific optical density under flaming and non-flaming conditions. It is also used for the extraction of toxic gas.

NBS Smoke Index Test Device is satisfied with standards (ASTM E 662, BS6401, ISO 5659, NES 711, NEPA 258, etc).

Using ISO 5659 conical radiant heat furnace, we can change the heating condition from 10KW/m2 to 5KW/m2 according to user's requirements.

In the test of NES 711, there are non-flaming test and flaming test in test conditions different from ASTM E 662.
The main principle is to measure smoke density in a particular space, cable or material produced under specific conditions of combustion or 713 radiation. The smoke will cause the beam attenuate when passes through the smoke, the light transmittance be use to calculate ratio of the optical density and smoke density. The smoke density chamber is designed according to ISO5659 standard. It has a conical radiant furnace, heat flux can be up 50 kW / m2, and laterally positioned sample, it also can test the sample mass loss rate.

 

 

Standards:

1, The device is consist of cabinet, sample case, the radiation cone, ignition, light and measuring devices and other relevant control device component;
2, The structural design and control design considers the ergonomics; The test box is designed with full door design approach; lock design for easy one-time close the door; optimize operational processes;
3, The equipment has fully opened door for easy loading and unloading of samples and cleaning the box;
4, The front door hinge installation with Windows and window has block the activity window opaque visor to prevent light from entering the sealed box;
5, The controller is located in the side of the box, easy to operate. When the door is closed,it does not affect the view controller;
6, Security flameout board is simple to replace with safer operation;
7, The test box is easy cleaning and coating chemical resistance.


Combustion System:
1, The heating cone: Power 2600W, input temperature range of 0 ~ 1000 ºC, can be stable within ± 2 ºC within 50 minutes, providing irradiance 10KW / m²-50KW / m².
2, The use of mass flow controllers and differential pressure sensor can improve the accuracy of piezometers and automatic leak test.
3, Ignition with automatic ignition devices; flame length 30mm±5mm; in accordance with standards prescribed blue flame with a yellow tip.


Smoke Density Measuring Sytem:
1, Smoke density and temperature are digital display, viewing more convenient, more accurate values.
2, Photodetector assembly includes a photomultiplier, amplified filters, shutters, filters, neutral density filter, a lens, an optical window, and other components.
3, The light source is 6.5V incandescent light sources.
4, The installation of optical cartridge box at the top, light accepted as side-on photomultiplier, light transmission rate of 0.001% accuracy can be achieved.
5, Achromatic lens.
6, Japan imported Photomultiplier tubes.
7, High-gain low-noise amplifier control circuit.


Control system:
1, Automatic completion of the test; automatic acquisition of various signals; And test report could be print from computer.
2.Dimension (mm): 2150 (H) x 1650 (L)x840 (D) .

3.Size of chamber: 610 mm (H) x 914 mm(L) × 914 mm (D).


Technical Parameter:
1, Light transmittance measurement range: 0 ~ 100%; Resolution is 0.00001%;
2, Accuracy of measurement is less than + / - 2.5%;
3, Light 6.5 V incandescent light; 2200+100k color temperature incandescent lamp;
4, Optical system for transmittance as linear response, measuring at least accuracy + / - 3%;
5, Photomultiplier tube filled with partial data acquisition precision 0.5%;
6, Heater input temperature 0 ºC ~ 1000 ºC, accuracy of plus or minus 2 ºC;
7, Import K type armoured thermocouple accuracy of 0.1 ºC;
8, Mouth thermopile type heat flow meter range is 0 ~ 80 kw/m2; The thermopile type heat flow meter, heat meter accuracy is 1%, repeatability and 0.5%;
9, Propane gas flow meter range: 0 ~ 100 ml/min. Minimum pressure of 3.5 kPa plus or minus 1 kPa;
10, Air flow meter range: 0 ~ 1000 ml/min.
11, Fan provides the negative pressure in the cabinet at least 0.5 kPa;
12, Enclosure bear greater than the atmospheric pressure at least 1.5 kPa;
13, Water pressure gauge 1.5 kPa (150 mm water column);
14, Wall temperature measurement range: 0 ~ 100ºC±1ºC;
15, Window heater power: 9 W;
16, Test the pressure inside the warehouse scope: < 1.5 kPa;
17, Radiation power range: 0 ~ 50 kW/m2.

 


Factory overview
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable

Customer Feedback 

Germany
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable
USA
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable
Transporation
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable
FAQ

1.What's the delivery time?

About 2 months .

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable pictures & photos
ASTM E662 Optical Smoke Density Test Device for Plastic and Cable
US $20,000-30,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters