UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test

Product Details
Customization: Available
After-sales Service: Response in 12 Hours
Warranty: 12 Months
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (17)
  • UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
  • UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
  • UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
  • UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
  • UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
  • UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
Find Similar Products

Basic Info.

Model NO.
HRR
Type
Finished Batteries Tester
Test Region
Heat Release Test
Application
Lithium-ion Battery
Customized
Non-Customized
Test Standard
UL9150A
Dimensions of Exhaust Hood
6 Meters*6 Meters
Diamter of Exhaust Pipe
1200mm
Capacity of Exhuast
More Than 60,000 M3/H
Range of Pressure Transducer
(0-200) PA
Gas Concentration
100×10-6
Temperature Sensor
Omega K Type Thermocouples
Material of Sampling Probe
SS304 Bar Typee
Sampling Capacity
40L/Min
Transport Package
Plywood Case
Specification
New
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
10 Sets/Month

Product Description

Introduction 

The Heat Release Calorimetry provides a means of determining the burning behavior of the material by measuring specific test responses when the test specimen is subjected to a specified flame ignition.

The test will be conducted in an opening exhaust hood, size in 6000mm * 6000mm, with a well ventilated conditions. The measurement to be made include the rate of heat and smoke release, total heat released, smoke released etc.


Exhaust Hood and Duct:
1.A stainless steel made hood is installed above the floor, size is 6 meters*6 meters.
2.The hood is used to collect the combustion gas and transfer to the exhaust pipe by the plenum chamber on the top.
3.The side skirt is installed underneath the edge of hood to improve smoke capture, made of glass fibre cloth, resistant to temperatures up to 1100°C.
4.The exhaust pipe is 1200mm in diameter and 8 times diameter in length.
5.The hood and duct are connected to the exhaust system that capacity not less than 60,000 m3/h.

Instrumental Section

  • The instrumental section is installed in the end of exhaust duct, equipped with thermocouples, differential pressure transducer, sampling probe, and white light system.

  • The flow sensors used in the exhaust duct is a bi-directional probe, the probes are made of 316 stainless steel.

  • The pressure transducer with a range of at least (0-200) Pa and an accuracy of ±2 Pa. Response time of 90% of the output of the pressure transducer is not more than 1s.

  • The Full Scale Calorimeter is equipped with 3 OMEGA K type thermocouples for temperature measurement, 24 AWG wire gage, measurement range up to 1000 degrees, accuracy of ± 0.75%.

  • White light measuring system, consisting of lamp, plano convex lenses, aperture, photocell.

  • The smoke measurement system is mounted on the integrated measuring section using a flexible joint diametrically opposite each other.

  • Bar type sampling probe, SS304 made, removable design for easy removal of particles build-up in the sampling probe, reducing system delay time.

Gas Sampling System

  • Three stages particle filters, 1st: Soot filter, glass fibre cotton, filtering large particles in the combustion gas; 2nd: PTFE filter, filtering rate up to 2 micron; 3rd: PTFE membrane, filtering rate up to 0.5 micron, effective moisture isolation.

  • Compressor cold trap, cool capacity up to 320KJ/h, temperature control accuracy up to 0.1 °C, static variation 0.1 °C, self-starting and maintenance-free.

  • Steam trap, automatic drainage of the cooling water generated by the cold trap, maintenance-free.

  • Dry the residual moisture in the sampling gas, with quick disassembly and replacement of the drying medium.

  • KNF vacuum sampling pump with a sampling capacity of 40 L/min, continuous sampling pressure of 50 KPa, high gas tightness, low noise and low vibration.

Gas Analysis System

  • Namebrand paramagnetic type O2 analyzer, measurement range of 0 to 25%, accuracy of ± 0.01%.

  • Namebrand NDIR type CO analyzer, measurement range of 0 to 1%, accuracy of ± 0.001%.

  • Namebrand NDIR type CO2 analyzer, measurement range of 0 to 10%, accuracy of ± 0.01%.

Calibration System

  • Sandbox burner, provides an even gas flow over the top.

  • Remote-controlled ignition device, pilot flame ignition with sparker.

  • Mass flow controller for flame source control, accuracy up to ±2%.

  • Auto flow control software.

Data Acquisition System

  • Gas concentration: 100×10-6;

  • Temperature: 0.1ºC;

  • DPT: 0.1Pa;

  • Time: 0.1s;

  • Other signal: 0.1% of F.S

Windows Software

  • Windows base operation software, interface in English.

  • Function includes, sensor monitoring, sensor calibration, system calibration (step calibration), heat release test, report export and management.



Factory overview

UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
Customer Feedback 

Germany
UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
USA
UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
Transporation
UL9150A Heat Release Calorimetry Full Scale Calorimeter for Battery Thermal Runaway Test
FAQ

1.What's the delivery time?

About 3 or 4 months.

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD250/Day for every person.

 