Customization: | Available |
---|---|
After-sales Service: | Response in 12 Hours |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1.Integrated design with a complete set of equipment installed in a movable floor-standing cabinet.
2.Integrated battery charging and discharging module for performing overcharging, heating, and puncture modes.
3.Synchronized data acquisition of voltage, current, temperature, pressure, and video recording.
4.Pressure-resistant container designed to withstand specific volume and pressure requirements, customizable for production.
Technical parameters
Heating temperature Range | Ambient to 300 ºC |
Heating rate | 4-7ºC /min |
Thermal Sensitivity of Heat Release Detection | ≥0.02ºC /min |
Pressure range | 0-20bar |
Pressure Detection Accuracy | 0.05% |
Working Mode | Temperature Rise - Insulation |
Container Volume | customizable |
Pressure Resistance of a Container | 2mpa,customizable |
Thermocouple | 8 or 16 pcs |
Thermocouple Temperature Resistance | Ambient to 1100ºC |
Pressure vessel, anti-corrosion steel made, with an internal volume of 82 liters.
The pressure vessel can withstand a maximum of 3MPa (435 PSI) explosion pressure while configured with an explosion relief valve for safety.
The explosion relief valve for automatic relief exceeds pressure when reaching 80% of the maximum limits.
Equipped with a sampling port for gas sampling, with a ball valve to control the opening/close.
With a sampling gas filtering device at the outlet, a filtering rate not less than 0.5 microns;
Vessel door lock device, if the vessel has internal pressure, the door can not be opened to protect the operator.
With observation window on the test vessel.
Atmospheric gas replenishment device to replenish the chamber with specific atmospheric gas (normally N2).
A thermal runaway trigger system, which can set thermal runaway conditions such as heating film, short circuit, overcharge, and discharge.
The heating element can heat at a specific rate up to 200°C, with an adjustable heating rate of 4 to 7°C per min.
With a vacuum pump, the capacity is not less than 2 liters per min.
Up to 8 simultaneous temperature data acquisition circuits, with a resolution of 0.1°C.
The temperature measurement system, which measures temperature changes within the chamber and can measure temperature changes at specific locations on the test vessel.
Dual pressure transducers for low and high range pressure measurement.
Lower pressure transducer, with a measuring range of -0.1 to 1.0MPa, an accuracy of ± 0.5%.
Equip with protection device to protect lower pressure transducer when the pressure is over range.
Higher pressure transducer, with a measuring range of 0 to 3.0 MPa, an accuracy of ± 0.5%.
Data acquisition system: temperature: 8 channels, voltage: 2 channels, pressure: 2 channels, sampling frequency: 10 Hz, time, resolution of 1 sec.
Window based software, function includes:
1) Parameter setting, includes pressure transducer, heating rate, valve controls, etc;
2) Data record & display: temperature, pressure transducer, time, voltage;
3) Data curves display;
4) Auto mode & manual mode;
5) Test report export.