IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument

Product Details
Customization: Available
After-sales Service: Response in 12 Hours 12 Months
Warranty: 1full Year
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (17)
  • IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
  • IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
  • IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
  • IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
  • IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
  • IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
Find Similar Products

Basic Info.

Model NO.
AIC52114
Test Standard
IEC 60134-1~2-2013
Power Supply
AC220V,50/60Hz,1A
Nominal Luminous Flux
2000lm~3000lm
Nominal Color Temperature
2800K~3200K
Lens Light Beam
1.5m±0.1m Adjustable
Chamber Dimensions
3m * 3m * 3m
Control
Computer
Control Cabinet Dimensions
600mm(W)×600mm(D)×1600mm(H)
Fan Shaft Height
200 ~ 300mm
Transport Package
Plywood Case
Specification
600mm×6000mm×1600mm
Trademark
Advanced Instruments
Origin
China
HS Code
9031809090
Production Capacity
10sets Per Month

Packaging & Delivery

Package Size
70.00cm * 70.00cm * 170.00cm
Package Gross Weight
1.000kg

Product Description

General Introduction                                                                                                                                          
The 3M cube  wire and cable smoke density tester is mainly used incable or optical cable combustion smoke density measurement system, which is in accordance with the latest GB/T17651 and lEC61034-2013 standards.
Test Index: Optical density (OD) and specific optical density (DS) of the smoke
Measuring Principle: Lambert - Beer Law
Measuring Method: The smoke density is expressed by the fraction of the light transmittance of smoke in the initial light transmittance measured by the optical system. Calculating the maximum specific optical density by the minimum percentage of light transmission.
Standards: 
• IEC 61034 -1~2 - 2013 
• GB/T17651.1~2-1998
 Technical parameters                                                                                                                                       
Burning device:
1.Use the long pole ignition devices to ensure the testing personnel's safety; stainless steel flame testing machine stand allocated with an automatic sample fixture.
2.Stainless Steel Alcohol Tray:
   Internal Dimensions of the Bottom: 210mm*110mm
   TopInternal Dimensions: 240mm*140mm
   Height: 80mm
Optical System:
1.Use the restructured optical system light source which is imported by Germany
2.The light receiver is made of imported high-resolution batteries
3.Tungsten Quartz Halogen Lamp: Voltage: DC 12V; Power: 100W
4.Nominal Luminous Flux: 2000lm ~ 3000lm
5.Nominal Color Temperature: 2800K ~ 3200K
6.Lens Beam: 1.5m ± 0.1m (adjustable)
7.Optical receiver composed of imported high-resolution silicon photocells
8.Test Software: Smoke density DAQ test software, optical path calibration system, 0 and 100% point calibration, desktop computer operation
9.Standard Fan: Fan shaft height 200 ~ 300mm; Blade diameter 300 ± 60mm; Air volume 7 ~ 15m³/min)
IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
 Technical specifications                                                                                                                                                    
• Control cabinet dimensions: 600mm(W)×600mm(D)×1600mm(H) 
• Power supply: AC 220V, 50/60Hz, 1A 
• Test chamber dimensions: 3m×3m×3m(prepared by users)
IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
IEC 61034 3m Cube (Wire and Cable) Smoke Density Apparatus Chamber for Fire Tester Instrument
FAQ                                                                                                                                                                    
1.What's the delivery time?
About 90~120days.
2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.
3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 
4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD280/Day for every person.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now