Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723

Product Details
Customization: Available
After-sales Service: Response in 12 Hours
Warranty: 12 Months
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (17)
  • Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
  • Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
  • Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
  • Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
  • Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
  • Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
Find Similar Products

Basic Info.

Model NO.
STF
Test Standard
UL910,Nfpa262,ASTM E84,UL723
Power Supply
AC 380V, 50/60Hz, 30A
Gas
Methane and Compressed Air
Dimension
1300 mm (L) X 1100 mm (D) X 2100 mm (H)
Weight
1700kg
Control
PC+Labview
Temperature Measuring Range
0 C ~1300 C
Light Source
0.5W Helium Neon Laser
Dimension of Combustion Chamber
305mm X 451mm
Language
English
OEM Service
Available
Color
Grey
Transport Package
Plywood Case
Specification
Stainless steel
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
30 Sets/Month

Product Description

Stucture

1. The Steiner Tunnel Test Furnace is made of stainless steel .The internal dimensions of the combustion chamber is 305mm x 451mm and long 7.6m with firebricks laying which has satisfactory insulation property.
2. All internal fixtures are stainless steel which is rust resistant and corrosion resistant.
3. A double-deck quartz glass observation window is used to observe the position of flame spreading.
4. The height of the Steiner Tunnel Test Furnace is suitable for personnel to see the burning state ,sampleinstallation adjustment .
5. The overall design of the combustion chamber cover is made of stainless steel and is equipped with heat-resistant and thermal insulation material.
6. Steiner Tunnel Chamber is equipped with hoisting hook device.
7. The sample holder is equipped with cooling water circulation support bracket, which is resistant to high temperature.
8. Steiner Tunnel chamber is equipped with 304 stainless steel sealed sink.
9. Dual burner distance from air inlet is 1320mm.
10. The exhaust pipe is made of stainless steel which is good looking and corrosion resistant.
 

Suspension Hardware

1. Two station lift at the same time. Computer control ensures smooth lifting.
2. Suspension Hardware can be moved up and down,left and right which is convenient for sample installation and commissioning.
3. Equipped with safety protection platform, convenient for sample installation and commissioning.

Combustion system

1.The 10kV spark igniter is equipped with a safety cease-fire device.The igniter is automatically positioned through the lever connected to the closing mechanism.
2.The combustion heat of the burner is automatically controlled by the gas flow system. The reading accuracy is 1%.
3.The heat output of the burner can be automatically controlled by computer. Equipped with Japanese mass flow controller.
4.Gas flow valve control system to avoid leakage caused by electromagnetic valve failure, resulting in explosion risk.
5.Frequency fan automatically controls wind speed inside the flue, fan power 3KW, voltage 380V
6.Gas pressure gauge and pressure regulating valve to control gas pressure accurately.
7.The Steiner Tunnel Test Furnace adopts imported gas flow control valve to control gas flow accurately

Test System

1.Smoke Density Test:smoke density is measured by incandescent light system.Color temperature 2900±100K;The current fluctuation range is + 0.5%;Linear output of smoke density value;With time compensation function.
2.The lens converts light into 20mm parallel beams; d/f < 0.04.
3.Detector:The spectral distribution corresponds to CIE;The accuracy of the chromatic standard function is + 5%;Thelinearity of output is less than 3% of transmittance or 1% of absolute transmittance.;The response time of system 90% is no more than 3S
4.The thermocouple is K type armored thermocouple, 0.5mm diameter; the temperature accuracy is 0.5 degrees.
5.Pressure sensor range 0~100pa; accuracy is + 2pad;The response time of pressure sensor 90% is 1s.
6.Environmental pressure accuracy of + 200Pa
7.System record time is at least 3S
8.System time recording accuracy 0.1s
9.Computer real-time display of smoke density generation curve
10.Option:The system is equipped with a camera system to observe the experimental process and record the characteristics of the burner residue after the implementation and combustion of the sample.
 

Smoke Density Test System
1.Light source: 0.5W helium neon laser imported from the USA
2.Photoelectric receiver imported from the USA:wavelength range 350-1100nm;Peak value corresponding: 0.65A/W;Maximum output current: 100mA;Gain control 70dB.
3.The Thorlabs filters (imported from the USA) to make smoke density testing more accurate.
4.Steiner Tunnel Combustion Chamber is equipped with compensation photoelectric detection system, effectively preventing light source fluctuation interference.


Pipe exhaust capacity:
1.Delta inverter accurately controls flue gas velocity.
2.Smoke exhausting ability: Measurement of wind pressure and wind speed with pitot tube and imported micro pressure transmitter.
3.Differential pressure transmitter:Measurement range 0~2000pa; accuracy: + 1%FS;Hysteresis + 0.1%FS; maximum linear pressure 69Kpa;The response time of pressure sensor 90% is 1S.
4.Smoke exhaust capacity: 8000m³/H
5.The wind speed signal is automatically fed back to achieve automatic wind speed closed-loop control, with more stable wind speed and strong anti-interference ability.

Wind speed test of combustion chamber
1.Set the speed of the Steiner Tunnel Combustion Chamber in the computer system, and monitor the wind speed in real time, then output the wind speed curve.
2.The speed range of the combustion chamber is 0~8m/s, and the wind speed measurement resolution is 0.001m/s
3.The detection range is 0 ~ 250Pa, the accuracy is ± 0.5Pa, and the system indication pressure test accuracy is ± 2Pa.
 
Temperature control collection
1.Steiner Tunnel Furnace Chamber Apparatus is equipped with 3 OMEGA K armored thermocouples to monitor the temperature change of the exhaust pipe, the accuracy is 0.1 C.
2.The parameters of the thermocouple:Less than 0.25mm wire diameter; temperature accuracy 0.1 degrees.
3.The temperature test range is 0 C ~1300 C.

Data acquisition and control system
1.Labview control system which is stable and reliable system;
2.Standard control cabinet, equipped with Dell computer, 19 "LCD display;
3.The system has 16 bits high precision data acquisition module.
4.System time recording accuracy 0.1s
5.Achieve real-time data monitoring and accurate recording;
6.Real time display of system operation status; sound and light alarm under fault condition;
7.Control cabinet can connect printer and print report.
8.With Sound alarm and alarm display function.
9.The control cabinet can be connected with computer.
10.PLC control system with functions of automatic ignition, ignition failure dete
11.The software interface and control panel interact to control the operation.

Installation requirements

1 Electrical AC 380V, 50/60hz, 30A
2 Ambient Temperature Operating 15°C to 35°C
3 Gas Methane and compressed air
4 Utility Crane
5 Size 1300 mm (L) x 1100 mm (D) x 2100 mm (H)
6 Weight 1700KG
7 Applicable standards UL910,NFPA262,ASTM E84,UL723



Factory overview

Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
Customer Feedback 

Germany
Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
USA
Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
Transporation
Steiner Tunnel Test Furnace for Surface Burning Characteristics by UL910, Nfpa262, ASTM E84, UL723
FAQ

1.What's the delivery time?

About 60 days.

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now