Introduction:
The Anti-ignition Test Apparatus simulates cigarettes and matches as the ignition source of the flame to test and evaluation of the anti-ignition characteristics of upholstered furniture.
This Anti-ignition Test Apparatus is applicable to the test and evaluation of the anti-ignition characteristics of mattresses, sofas and other soft furniture used in public places, and the anti-ignition characteristics of soft furniture packages.
Standard:
GBT 18029
ISO8191-1~2
EN 1021
BS 5852
EN 597-1~2
Test Apparatus
1,The test rig is made of stainless steel plate which is corrosion resistant.
2,The Anti-ignition Test Apparatus has independent gas control cabinet.
3,Test rig dimension:Back frame 450mm X 300mm.Base frame 450mm X150mm.(GBT 18029,ISO8191-1~2,EN 1021)
4,Option 1:Back frame 450mm X 450mm.Base frame 450mm X300mm.(BS 5852)
5,Option 2:EN597 test rig is optional.Dimension is 450mm X 450mm.(EN597-1~2)
6,The Anti-ignition Test Apparatus is equipped with metal needles for puncturing cigarettes.
7,The diagonal length of steel mesh is 28mm.
Butane Flame Control System
1,Independent gas control cabinet.Size 570*400*420mm.
2,The Anti-ignition Test Apparatus adopts imported gas flow meter accurately displays gas flow rate of 0-500 ml/min.
3,With functions of 1 hour arrival reminder.
4,Imported needle valve accurately control gas flow rate.
5,Stainless steel burner, external diameter 8mm ± 0.1mm, inner diameter 6.5mm ± 0.1mm, length 200 ± 5mm.
6,The burner angle can be adjusted horizontally and vertically.
7,Imported gas pressure regulating valve is supplied with Anti-ignition Test Apparatus.
8,Precision gas gressure gauge.
9,The accuracy of the timer is 1 s.
10,The environmental temperature of the test is 10ºC~30ºC and the relative humidity is 15.0%~80%.
Technical parameters
1.Timing range: 0-999S, display and recording continued burning or smoldering time, fabric cracking time, the specimen's flame off time,
2.Test distance of igniter: 20-80 adjustable, with automatic movement and evacuation ignition mechanism.
3. The flow measurement range: 10 ~ 100m1 / min
4.Hose: Length should be (2.5 ~ 3mm) inside diameter of (7 ± 1mm) and connected to the stainless steel combustion pipe
5. Flow control system: Including a flow meter, trim valve, switch valve and regulator.
6. Flow (45 ± 2) ml / min need to provide the nominal output pressure 2.8kpa.
Factory overview