Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142

Product Details
Customization: Available
After-sales Service: Response in 12 Hours
Warranty: 12 Months
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (17)
  • Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
  • Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
  • Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
  • Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
  • Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
  • Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
Find Similar Products

Basic Info.

Model NO.
AIC-8142
Test Standard
ISO 8142,ASTM C411-82,ASTM C447-85
Test Area
900 * 450mm
Length of Heating Pipe
2 Meters
Measuring Temperature
0-1100 ºC
Thermocouple Accuracy
± 0.5%
Diameter of Thermocouple Wire
0.40mm
Heating Rate
5 ºC / Min or 3 ºC / Min
Heating Power
6kw
Delivery Time
30 Days
Test Object
Thermal Insulation Materials etc
Nominal Diameter
88mm, 108mm, 133mm
Function
Evaluate The Maximum Operating Temperature
Display
Touch Screen
Language
English
Transport Package
Plywood Case
Specification
Stainless steel
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
20 Sets/Month

Product Description

Introduction:

This maximun operating temperature tester is designed according to ISO 8142: 1990 ,which is used to evaluate the maximum operating temperature of loose-fill insulation materials, carpets, blankets, blocks, plates, prefabricated pipe insulation and some insulation products.

The maximun operating temperature tester adopts CNC machine processing molding. circular modelling is beautiful and generous. It can also be rust corrosion. Other parts use 45 # steel. The surface plating uses SUS304 stainless steel.

 

 
Standard:
• ASTM C411-82 "hot surface temperature insulation performance test method"
• ASTM C447-85 "insulation maximum use temperature assessment methods."
• ISO 8142: 1990 Appendix A "pre-determined maximum use of mineral wool pipe shell temperature of the test method."


Main features:

1. Heating plate: the heating plate is made of SUS304 stainless steel.the test area is about 900 * 450mm, which is surrounded by 80mm wide protective layer. At least five thermocouples which is ued to measure the surface temperature is located at the surface of the heating plate. Four thermocouples are fixed on the diagonal of heating plate heating zone, and the distance of each corner is about 150mm. The fifth thermocouple is located at thecentreof the heating plate.
2. Heat pipe: the heating pipe is made of SUS304 stainless steel.the length is about 2M, the nominal diameters are about 88mm, 108mm, 133mm. Three heating pipes are arranged side by side.
3. Temperature system: K-type thermocouplewire ;thermocouple wire diameter of 0.40mm, measuring temperature: 0-1100 ºC. Thermocouple Accuracy ± 0.5%.
4. The precision of heat difference about temperture thermocouple :5% or 15 ºC
5. The maximun operating temperature tester uses PLC temperature module to collect the temperature data.
6. The control section: PLC module, real-time displayed temperature curve is controlled by micro computer, the output report.
7. Heating rate: 5 ºC / min or 3 ºC / min can be set.
8. Touch screen control system: real-time displayed temperature curve;
9. 1m flat feet and minimum thickness feeler is about 0.03mm, 0.05mm;
10. A set of test software is supplied with maximun operating temperature testing equipment.
12. Heating power: 6kw
13. Temperature measurement: once every 2min collection and displayed with temperature curve;
14. Response time of the thermocouple: <0.5s
15. The precision of temperture: ± 0.5 ºC
16. The precision of time recorder: 1s/h
18. Flat ruler and feeler gauge: Measuring warpage.
19. Two sample canisters are supplied with Thermal Insulation Materials Maximum Operating Temperature Tester.

 

Factory overview

Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
Customer Feedback 

Germany
Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
USA
Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
Transporation
Maximum Operating Temperature Tester for Thermal Insulation Materials by ISO 8142
FAQ

1.What's the delivery time?

About 50 working days.

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.

 