• Intelligent Gas Chromatography for LPG Composition Analysis
  • Intelligent Gas Chromatography for LPG Composition Analysis
  • Intelligent Gas Chromatography for LPG Composition Analysis
  • Intelligent Gas Chromatography for LPG Composition Analysis
  • Intelligent Gas Chromatography for LPG Composition Analysis
  • Intelligent Gas Chromatography for LPG Composition Analysis

Intelligent Gas Chromatography for LPG Composition Analysis

After-sales Service: Response in 12 Hours
Warranty: 12 Months
Appliance: Petrochemical
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Intelligent Gas Chromatography for LPG Composition Analysis pictures & photos
Intelligent Gas Chromatography for LPG Composition Analysis
US $5,000-10,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
A91P
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
0.2~0.5mm
Test Standard
ASTM D2863,ISO 4589-2,Nes 714
Power Supply
220V, 50Hz
Weight
8kg
Dimension
420 mm (W) X 350 mm (D) X 560 mm (H)
Gas Supplies
Oxygen,Nitrogen and Propane
Color
White
Display
Digital
Repeatability
±0.1% Oxygen
Linearity
±0.1% Oxygen
Oxygen Sensor
Paramagnetic Type
Transport Package
Plywood Case
Specification
Stainless steel
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
50 Sets/Month

Product Description

1.Introduction
The gas chromatography is equipped with an automatic gas flow control module in the inlet, detector, and auxiliary gas module. The hydrogen flame ionization detector can be automatically ignited, hydrogen leakage is automatically protected, and it is safe and reliable. The special ceramicized amplification board is always stable in the wet season.
The gas chromatograph
y is equipped with fully imported gas and liquid valves, which can be automatically controlled, sequence operation, stable performance and convenient operation. The current mainstream imported capillary chromatographic column is used in the scheme configuration, which has excellent performance and long service life, can achieve good separation effect and peak shape, and improve the accuracy and stability of analysis.


2.Working condition
2.1 The site is well ventilated, without corrosive substances and no overhanging obstacles.
2.2 The temperature of the site should be between 15ºC~35ºC, the recommended range is between 20ºC~27ºC.
2.3 The humidity of the site should be within the relative humidity: 5%~95%, the recommended range is between 50%~60%.
2.4 Recommended altitude, up to 2000 m
2.5 The GC machine equipped with electronic pneumatic control (EPC) has a width of 59cm (23in), a height of 50cm (21in), and a thickness of 50cm (21in).
2.6 Leave at least 20cm (10in) of space behind the instrument to allow hot air to diffuse.
2.7 The input voltage range is 220V±10%, the ground voltage is less than 2.5V and greater than 0V, the maximum power is 2250VA
2.8 The purity of all gases is ≥99.999%, and the air is zero grade or better.

3.Technical specifications
Column oven
Furnace size: ≥28×30×18 cm
Operating temperature range: room temperature +4ºC~450ºC
Temperature program: 20 steps and 21 platforms
Temperature setting accuracy: 0.01ºC
Program heating speed: 120ºC/min
Method running time: 0--999.99min
Cooling speed from 450ºC to 50ºC is less than 460s
Runable column loss compensation (dual channel)
With automatic protection function of oven temperature

Inlet
Split/splitless capillary column injection port
High-precision electronic pressure/flow control
Temperature range: room temperature +5°C~450°C
Pressure setting range: 0-100psi
Pressure control accuracy: 0.001psi
Flow setting range: 0~1000mL/min
Flow setting accuracy: 0.001 mL /min
Maximum split ratio: 1:7500
Correction function: It can maintain the average linear velocity of the column in the heating of the column oven

Packed column inlet
Flow setting range: 0~100ml/min
Program ratio setting range: -400~400ml/min
Pressure control accuracy: 0.001psi
Flow setting accuracy: 0.001 mL /min
Correction function: maintain the column flow during the heating of the column oven

Detector
Flame Ionization Detector (FID)
High-precision electronic flow/pressure control, adapted to packed columns and capillary columns
Maximum use temperature :450°C
Minimum detection limit: <1.50 pg/s (Dodecane)
Automatic ignition function
Dynamic linear range: 107 (+10%)
Data collection frequency: up to 200HZ

Micro Cell Thermal Conductivity Detector (u-TCD)
High-precision electronic flow/pressure control, adapted to packed columns and capillary columns
Maximum operating temperature: 400°C
Detection limit ≤1500 pg/ml (benzene-toluene)
Sensitivity ≥5000 mV·mL/mg (benzene-toluene)
Baseline drift (30 min) ≤0.2mV
Baseline noise≤0.1 mV
Dynamic linear range ≥105
Data collection frequency: up to 500Hz


Unique fluid switching design (single-filament micro-cell), quickly reach equilibrium (within 5min) after starting the switch, low drift
Instrument control and monitoring, method editing and storage
The chromatographic workstation Panna ChemLab communicates with the chromatograph through a networked interface, which can fully control all the parameters of the gas chromatograph, such as temperature, pressure, flow, split ratio, and the operation of valves and autosamplers. It can ensure the accuracy of each parameter setting. The stability of the test method. The editing, creation, modification, saving and recall of the method can all be carried out on the chromatographic workstation without any parameter setting on the instrument host, which is simple, convenient and easy to use, efficient and accurate. The Chinese keyboard monitors the working status of the instrument in real time.
The core of the software version adopts multi-threaded processing mode, so that instrument control, data acquisition, data processing and other application software running at the same time will not interfere with each other, and the stability of the system is greatly improved.
Instrument failure and maintenance can be automatically recorded by the built-in electronic tracking system
A91 GC machine has a built-in fault feedback and diagnosis system, which can track and automatically record the working conditions, faults and maintenance of the instrument in real time, providing a strong basis for the maintenance and troubleshooting of the instrument.


Intelligent Gas Chromatography for LPG Composition Analysis
Customer Feedback 

Germany
Intelligent Gas Chromatography for LPG Composition Analysis
USA
Intelligent Gas Chromatography for LPG Composition Analysis
Package
Intelligent Gas Chromatography for LPG Composition Analysis
FAQ

1.What's the delivery time?

About 40 days .

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Intelligent Gas Chromatography for LPG Composition Analysis pictures & photos
Intelligent Gas Chromatography for LPG Composition Analysis
US $5,000-10,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters