• Automatic Power Transformer Impedance and Load Tester
  • Automatic Power Transformer Impedance and Load Tester
  • Automatic Power Transformer Impedance and Load Tester
  • Automatic Power Transformer Impedance and Load Tester
  • Automatic Power Transformer Impedance and Load Tester
  • Automatic Power Transformer Impedance and Load Tester

Automatic Power Transformer Impedance and Load Tester

After-sales Service: Response in 12 Hours
Warranty: 12 Months
Test Standard: IEC 60076-5
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Automatic Power Transformer Impedance and Load Tester pictures & photos
Automatic Power Transformer Impedance and Load Tester
US $2,000-5,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
TIT-4
AC Impedance
0~999.999Ω 0.2%±2 Digits
AC Voltage
0~600V 0.2%±2 Digits
AC Current
0~120A 0.2%±2 Digits
Active Power
0.5% or 1.0%
Frequency
45~65Hz 0.1%
Dimension
49X31X25cm3
Weight
8kg
Power Supply
AC220V±10%, (50 or 60)Hz
Printer
Inbuit
Display
LCD
Application
Transformer Testing
Language
English
OEM Service
Available
Transport Package
Plywood Case
Specification
Small
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
50 Sets/Month

Product Description

I. Introduction:
Power transformer as an important electrical equipment, its safe and reliable operation is extremely important for power systems. After the impact of short-circuit current, the transformer winding deformation test is very important.
To short-circuit the low-voltage winding side of the transformer and apply a low voltage of the operating frequency (50Hz or 60Hz normally) to the high voltage winding side of the transformer, the short-circuit impedance method measures the short-circuit impedance of the operating frequency.
The test result is mainly leakage reactance component, determined by the geometry of the winding. The change of the transformer winding structure will cause changes of the transformer leakage reactance, resulting in transformer short circuit impedance numerical changes.

The Automatic Power Transformer Impedance and Load Tester follows the national power industry standards DLT 1093-2008, and can meet requirements of IEC60076-5-2006 also.
The Transformer Impedance and Load Tester can also be used for generator rotor AC impedance test, transformer load and no load loss test.

 

II.Main Features

1.The Transformer Impedance and Load Tester uses six channels of AD chip of 16 bits;
2.This tester has seven inch LCD touch screen of which the brightness can be adjusted;
3.The Transformer Impedance and Load Tester has thermal printer of which the print thick can be adjusted;
4.It could store fifty groups of SCI data and thirty groups of GAI data, which could be read to current screen or upload to the PC;
5.The tester has PC software,by which we could upload data ,test, analyze data, print data, or create word document;
6.The Transformer Impedance and Load Tester adopts USB2.0 to connect to the device.

 

III. Specifications:

AC impedance 0~999.999Ω 0.2%±2 digits
AC voltage 0~600V 0.2%±2 digits
AC current 0~120A 0.2%±2 digits
Active power cosφ>0.1  0.5%±2 digits
cosφ<0.1  1.0%±2 digits
Reactive power 0.2%±2 digits
Frequency 45~65HZ 0.1%
Dimension 49X31X25cm3
Weight 8KG
Power supply AC220V±10%, (50 or 60)HZ
Working condition -10ºC~50ºC ; humidity <90%
 
 

Factory overview

Automatic Power Transformer Impedance and Load Tester
Customer Feedback 

Chile
Automatic Power Transformer Impedance and Load TesterGermany

Automatic Power Transformer Impedance and Load Tester
USA
Automatic Power Transformer Impedance and Load Tester
Transporation
Automatic Power Transformer Impedance and Load Tester

FAQ

1.What's the delivery time?
About 15 working days.

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Automatic Power Transformer Impedance and Load Tester pictures & photos
Automatic Power Transformer Impedance and Load Tester
US $2,000-5,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters