ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)

Product Details
Customization: Available
After-sales Service: Response in 12 Hours 12 Months
Warranty: 1full Year
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (17)
  • ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
  • ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
  • ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
  • ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
  • ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
  • ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
Find Similar Products

Basic Info.

Model NO.
AIC-525
Power Supply
AC(220±5%)V 50Hz
Applicable Standard
ASTM D525, ISO 7536
Temperature Control Mode
Pid Temperature Control Technology
Temperature Control Accuracy
100±0.1℃
Working Units
Two Oxygen Bombs
Pressure Correction
External Pressure Calibrator
Test Method
Induction Period Method
Printer
Inbuilt
Power Consumption
1.5 Kw
Transport Package
Hardboard
Specification
630mm*560mm*490mm
Trademark
Advanced Instruments
Origin
China
HS Code
9031809090
Production Capacity
20sets Per Month

Packaging & Delivery

Package Size
75.00cm * 66.00cm * 60.00cm
Package Gross Weight
50.000kg

Product Description

ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
Product Introduction
This gasoline oxidation stability tester is used to determine the stability of gasoline in finished form only, under accelerated oxidation conditions.The induction period may be used as an indication of the tendency of motor gasoline to form gum in storage.
 Product Features
1.The instrument is controlled by a microcomputer, which can perform two groups of tests simultaneously. The whole test process and printing of test data are carried out automatically.
2.Large touch screen interface displays hyperbolic curves (including temperature control status, pressure curves, test data, average values, etc.), making the entire test process clear at a glance.
3.The instrument is equipped with an automatic leak detection function, which greatly reduces the workload of operators.
4.Imported components are adopted for the control part of the instrument, ensuring high reliability.
5.The instrument features test failure and fault alarm display, facilitating fault diagnosis.
ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
Technical Parameter

Applicable standard
GB/T 8018, ASTM D525, ISO 7536, DIN 51780, IP 40
Temperature Control Mode
PID temperature control technology, automatic temperature control
Temperature Control Accuracy
100±0.1℃
Display Content
1.Control temperature and set temperature;
2.Sample number;
3.Time/pressure logarithmic curve (dual channels displayed simultaneously);
4.Test results;
5.Fault prompts, etc.
Working Units
Two oxygen bombs
Pressure Correction
External pressure calibrator can be connected to correct pressure deviation
Connection Mode
Imported stainless steel quick connector, leak-free
Power Consumption:
1.5KW
Power Supply
220V, 50Hz
Instrument Dimensions
630×560×490 mm
Net Weight
42kg
ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
ASTM D525 / ISO 7536 Automatic Gasoline Oxidation Stability Tester (Induction Period Method)
FAQ
1.What's the delivery time?
About 30days.
2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.
3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 
4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.