IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable

Product Details
Customization: Available
After-sales Service: Response in 12 Hours
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Fast Delivery
The supplier can deliver the goods within 30 days
QA/QC Inspectors
The supplier has 1 QA and QC inspection staff
to see all verified strength labels (17)
  • IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable
  • IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable
  • IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable
Find Similar Products

Basic Info.

Model NO.
AIC-60331A
Standards
IEC 60331
Overall Dimension
1,600 (W) × 850 (D) × 1,650 (H) mm
Controller Size
600 (W) × 750 (D) × 1,200 (H) mm
Weight
300kg
Flame Temperature
0 ~ 1100 ºC Adjustable
Timing Range
0 ~ 999min
Max.Power
5000va
Power Supply
AC 380V 3-Phase, 50 / 60Hz, 30A
Color
White
Test Object
Fire Resistant Cable or Optical Cable
Transport Package
Plywood Case
Specification
Automatic
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
20 Sets/Month

Product Description

Introduction:
Fire-resistant cable refers to the cable that can keep a safe running time in the case of flame combustion.
This Fire Resistance test equipment is designed according to the requirements of IEC60331-11,and used to obtain the refractory characteristics of a fire resistant cable or optical cable under flame conditions.


Standards
• IEC 60331 Part 11:Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 degree C

• IEC 60331 Part 21:Specifies the test procedure and gives theperformance requirement, including a recommended flame application time, for cables of rated voltages up to and including 0,6/1,0 kV required to maintaincircuit integrity when subjected to fire under specified conditions
 

 

Main Features:
1, All fixtures of Wire and Cable Fire Resistance Characteristics Test Equipment are made of stainless steel;
2, The burner is a belt type propane blowtorch with a Venturi mixer, and the burner nozzle is length 500mm, width 15mm;
3, Those burning holes are staggered into 3 rows, and the front width is 15mm, holes diameter is 1.32mm and these holes center distance is 3.2mm;
5, One end of the specimen holder is equipped with a clamp to fix the sample, and the other end is convenient for heat transfer along the longitudinal specimen;
6, The cable sample is supported by two metal rings, and the middle length of the two rings is about 300mm;
7, An inner diameter of the sample supporting metal rings is 150mm, and the cross-sectional diameter of the ring is 10 ± 2mm.
8, The position of the burner torch from burning the bottom is not less than 200mm, and not less than 300mm from the tank wall.
 

 

Combustion System:
1, Independent standard electrical control platform;
2, With intelligent detection function, when a short circuit in the sample during the test, automatic alarm and turn off the fire source.
3, Fuse current in the experimental circuit is 2A;
4, The sample is applied to power of AV 100V ~ 1000V adjustable;
5, The time can be set free for the fire, the time recommended by standards is 90min.
 

 

Technical Specifications

1 Power supply AC 380V 3-phase, 50 / 60Hz, 30A
2 Overall dimension 1,600 (W) × 850 (D) × 1,650 (H) mm
3 Console size 600 (W) × 750 (D) × 1,200 (H) mm
4 Weight 300KG
5 The input voltage 0 ~ 1000V; can be adjusted
6 Maximum power 5000VA
7 Timer 0 ~ 999min
8 The flame temperature 0 ~ 1100 ºC adjustable
9 The test load current 0.25A, can be adjusted

 


 

Factory overview
IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable
Customer Feedback 

Germany
IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable
USA
IEC 60331-11 & 21 Fire-Resistant Property Test Equipment Wire and Cable
FAQ
1.What's the delivery time?

About 15 days.

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every perso

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier