Introduction:
This Flammability of Upholstered Furniture Testing Equipment simulates cigarettes and matches as the ignition source of the flame to test and evaluation of the anti-ignition characteristics of upholstered furniture.
This equipment is applicable to the test and evaluation of the anti-ignition characteristics of mattresses, sofas and other soft furniture used in public places, and the anti-ignition characteristics of soft furniture packages.
Standard:
GBT 18029
ISO8191-1~2:1988,
EN 1021
BS 5852
EN 597-1~2:1995
Test Apparatus
1,The test rig is made of stainless steel plate which is corrosion resistant.
2,The Flammability of Upholstered Furniture Testing Equipment has independent gas control cabinet.
3,Test rig dimension:Back frame 450mm X 300mm.Base frame 450mm X150mm.(GBT 18029,ISO8191-1~2,EN 1021)
4,Option 1:Back frame 450mm X 450mm.Base frame 450mm X300mm.(BS 5852)
5,Option 2:EN597 test rig is optional.Dimension is 450mm X 450mm.(EN597-1~2)
6,The Flammability of Upholstered Furniture Testing Equipment is equipped with metal needles for puncturing cigarettes.
7,The diagonal length of steel mesh is 28mm.
Butane Flame Control System
1,Independent gas control cabinet:570*400*420mm.
2,The Anti-ignition Characteristics Testing Machine adopts imported gas flow meter accurately displays gas flow rate of 0-500 ml/min.
3,With functions of 1 hour arrival reminder.
4,Imported needle valve accurately control gas flow rate.
5,Stainless steel burner, external diameter 8mm ± 0.1mm, inner diameter 6.5mm ± 0.1mm, length 200 ± 5mm.
6,The burner angle can be adjusted horizontally and vertically.
7,Imported gas pressure regulating valve is supplied with Flammability of Upholstered Furniture Testing Equipment.
8,Precision gas gressure gauge.
9,The accuracy of the timer is 1 s.
10,The environmental temperature of the test is 10ºC~30ºC and the relative humidity is 15.0%~80%.
Technical parameters
1.Timing range: 0-999S, display and recording continued burning or smoldering time, fabric cracking time, the specimen's flame off time,
2.Test distance of igniter: 20-80 adjustable, with automatic movement and evacuation ignition mechanism.
3. The flow measurement range: 10 ~ 100m1 / min
4.Hose: Length should be (2.5 ~ 3mm) inside diameter of (7 ± 1mm) and connected to the stainless steel combustion pipe
5. Flow control system: Including a flow meter, trim valve, switch valve and regulator.
6. Flow (45 ± 2) ml / min need to provide the nominal output pressure 2.8kpa.