• ISO13506 Instrumented Manikin Flame Engulfing Test Device
  • ISO13506 Instrumented Manikin Flame Engulfing Test Device
  • ISO13506 Instrumented Manikin Flame Engulfing Test Device
  • ISO13506 Instrumented Manikin Flame Engulfing Test Device
  • ISO13506 Instrumented Manikin Flame Engulfing Test Device
  • ISO13506 Instrumented Manikin Flame Engulfing Test Device

ISO13506 Instrumented Manikin Flame Engulfing Test Device

After-sales Service: Response in 12 Hours
Warranty: 12 Months
Test Standard: ISO13506 and ASTM F1930
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
ISO13506 Instrumented Manikin Flame Engulfing Test Device pictures & photos
ISO13506 Instrumented Manikin Flame Engulfing Test Device
US $1,000,000-1,100,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
BMS
Floor Spare
14m*6m*6m
Thermal Radiation Range
0-167kw / M2
Weight
2000kg
Standard of Manikin
ASTM D6240
Quantity of Sensor
122
Volume of Chamber
4m Long X 3.5m Wide X 3m High
Burner
12 PCS
Delivery Time
About 6 Months
Application
Safety Protection
Control
PC
OEM Service
Available
Language
English
Transport Package
Plywood Case
Specification
Stainless steel
Trademark
AI
Origin
China
HS Code
9031809090
Production Capacity
30 Sets/Month

Product Description

Introduction:

The Manikin Flame Engulfment Test Equipment conforms to ISO13506 and ASTM F1930 standards.

To empirically evaluate the performance of a garment in a simulated flash fire environment that controls the heat flux, flame distribution and duration of the flame test manikin.

The Instrumented Manikin Flame Engulfment Test Equipment can be used to analyze the burn range and measure the time of 2nd and 3rd degree burn using this system."

 

About System:

The test equipment is mainly composed of test chamber,control system, manikin, data acquisition system, image acquisition system and software. It can calibrate the uniformity of incident heat flow, collect and calculate the temperature of epidermis, dermis and subcutaneous tissue, complete the analysis of first degree burn, second degree burn and pain, predict the degree and scope of burn, so as to complete the protection clothing definition of protective properties.

 

Manikin:

  • The Instrumented Manikin Flame Engulfment Test Equipment meets the requirements of ISO 13506 and ASTM f1930, and the manikin size meets the requirements of ASTM D6240;
  • The manikin model is made of non degradable and fireproof ceramic composites;
  • The manikin has joints of shoulder, elbow, knee and ankle;
  • The connecting cable is connected into the manikin body from the top of the head or the back neck;
  • 122 sensors were distributed throughout the manikin;

 

Sensors:

  • The sensor is made of copper alloy, and thermocouple is welded on the back of sensor to measure the temperature change of copper plate;
  • The thermal radiation range is at least 0-167kw / m2;
  • The sensor surface is sprayed with black high temperature resistant paint;
  • The response time of thermal sensor is less than or equal to 0.1s;

 

Test chamber:

  • The test chamber is constructed of fire-resistant quartz glass and steel structure. The volume of chamber is 4m long x 3.5m wide x 3m high;
  • The chamber provides a uniform flame for the test surface of the manikin and provides sufficient space for debugging;
  • The chamber shall be provided with independent ventilation equipment to ensure sufficient oxygen supply during the test, and exhaust gas shall be drained after the test;
  • The exhaust rate of fan is adjustable, and the exhaust air volume is at least 25m3 / min; it can also provide cooling air with smaller exhaust air volume;
  • Combustible gas leakage detector and door opening and closing detector are equipped in combustion chamber to ensure personnel and test safety;

 

Control system:

  • 12 imported burner were used and divided into 6 groups, 2 in each group
  • The burner array is composed of hexagonal layout to provide uniform incident heat flow of at least 84kw / m2 for the manikin surface;
  • The gas pipeline is arranged with stainless steel pipe, and the flame retardant hose is used to connect with the burner group;
  • The inlet explosion-proof solenoid valve controls the gas on-off, and the response time is 0.1s;
  • The gas flow is controlled by mass flow controller to accurately control the gas flow to ensure the stability and repeatability of the fire site;
  • The burner is equipped with a long open fire igniter for safe pilot fire. During the pilot fire test, the combustion state is maintained throughout the whole process to ensure the ignition safety;

 

 

Data acquisition system:

  • Computer + Labview realizes multi-channel high frequency data sampling and analysis system;
  • Adopt imported brand data acquisition platform and Ethernet connection to realize time synchronization distributed measurement;
  • The imported brand temperature acquisition module is adopted, the sampling frequency is 95hz / channel, the sampling accuracy is ± 0.29 ºC, and the resolution is 0.01 ºC;
  • Using Labview software platform to achieve synchronous data acquisition, display and record;
  • 124 sensors and temperature environment data are collected synchronously;

 

Software:

  • The system test software adopts Labview editing, modular design, simple interface and rich data content;
  • The temperature and heat flow of each channel can be calibrated, and each channel sensor is equipped with a correction curve;
  • The Instrumented Manikin Flame Engulfment Test Equipment adopts 2nd degree burn calibration of sensor;
  • The gas flow of each channel can be set;
  • Exposure condition calibration: the manikin with sensor calibrated is placed in a blast environment to confirm the heat flux value, average value and standard deviation of each channel;
  • 2nd degree burn area analysis of manikin surface;
  • 3rd degree burn area analysis of manikin surface;
  • Total burn area analysis of manikin surface;
  • Total heat absorption analysis of manikin surface;

Factory overview

ISO13506 Instrumented Manikin Flame Engulfing Test Device
Customer Feedback 

Germany
ISO13506 Instrumented Manikin Flame Engulfing Test Device
USA
ISO13506 Instrumented Manikin Flame Engulfing Test Device
Transporation
ISO13506 Instrumented Manikin Flame Engulfing Test Device
FAQ

1.What's the delivery time?

About 6 months.

2.What's your payment terms?
30% paid by T/T in advance,70% paid by by T/T before shipping.

3.What's your guarantee terms?
The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

4.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
ISO13506 Instrumented Manikin Flame Engulfing Test Device pictures & photos
ISO13506 Instrumented Manikin Flame Engulfing Test Device
US $1,000,000-1,100,000 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
>2000 square meters